VS-616G5 Option Instruction Manual: InterBus-S Control Card SI-R

Page 9

The local bus is for use inside the control cabinets. The local bus carries signals,
power, and control to the local bus I/O modules.

The installation remote bus is used mainly in IP65 or IP67 environments and is a
remote bus with 24VDC power for remote installation I/O modules.

The scan time of the InterBus-S system depends on the various factors and increases
linearly with an increasing number of I/O points. However, due to the efficiency of the
InterBus-S protocol, the scan time is predominantly determined by the number of I/O
points.

The SI-R option card for the VS-616G5 is a remote bus device only.

Controlling the Inverter Via InterBus-S

The option board is a 4 word InterBus-S remote bus slave unit with a 1 word PCP
channel. This means that the board can exchange data in two ways:

1. Through the InterBus-S fast cyclic data (3 words) of 16 bit data

2. Through PCP (Peripheral Communication Protocol)

Cyclic data

The board supports 3 words of fast cyclic data. The data exchanged supports the
following functions and parameters:

Input data

(IBS master

⇒ VS-616G5)

* 1770 hex = 60.00Hz

Table 5: Basic Remote Bus Specifications

Maximum length of remote bus segment

400m

Maximum bus cable length between:

Host and first remote bus module

Two remote bus modules

Host and last remote bus module

400m

400m

12.8 km

Transmission rate

500kbits/s

Transmission medium

RS-422

Word 0

Word 1

Word 2

Word 3

Fast data w0

Fast data w1

Fast data w2

PCP

Not used

Run Operation Signals

(See Table 6)

Speed command

(1hex = 0.01Hz)*

Used by PCP protocol