7 modbus tcp/ip messaging – Yaskawa Modbus TCP/IP SI-EM3D User Manual

Page 31

Advertising
background image

Addre

ss

(hex)

Drive

Regist

er

(hex)

Description

Bit

Description

200A

C1

Error Signal 2

0

External Fault at input terminal S3 (EF3)

1

External Fault at input terminal S4 (EF4)

2

External Fault at input terminal S5 (EF5)

3

External Fault at input terminal S6 (EF6)

4

External Fault at input terminal S7 (EF7)

5

External Fault at input terminal S8 (EF8)

6

Cooling fan Error (FAn)

5

Reserved

6

Reserved

7

Overspeed (os)

8

Excessive Speed Deviation (dEv)

9

PG Disconnected (PGo)

A

Input Phase Loss (PF)

B

Output Phase Loss (LF)

C

Motor Overheat (PTC input) (oH3)

D

Digital Operator Connection Fault (oPr)

E

EEPROM Write Error (Err)

F

Motor Overheat Fault (PTC input) (oH4)

7 Modbus TCP/IP Messaging

YASKAWA TOEP YAICOM 18A 1000-Series Option Dual-Port Modbus TCP/IP SI-EM3D Installation Manual

31