B Parameter Table

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

181

Pa

ra

me

te

r T

abl

e

B

H1 Multi-Function Digital Input Settings

H1-

Setting

Function

Description

3

Multi-Step Speed Reference 1

When input terminals are set to Multi-Step Speed References 1 through 3, switching
combinations of those terminals will create a multi-step speed sequence using the speed
references set in d1-01 through d1-08.

4

Multi-Step Speed Reference 2

5

Multi-Step Speed Reference 3

6

Jog reference selection

Closed: Jog frequency reference (d1-17) selected.
The Jog frequency can be used when the speed reference selection is not assigned to input
terminals (b1-01

≠ 1) and the speed reference priority is set to use the multi-step speed reference

(d1-18 = 0 or 3).

7

Accel/decel Ramp Selection 1

Used to switch between accel/decel ramp 1 (set in C1-01, C1-02) and accel/decel ramp 2 (set in
C1-03, C1-04).
When combined with another input terminal set for "Accel/Decel ramp 2" (H1-

= 1A), the

drive can also switch between accel/decel ramp 3 (set in C1-05, C1-06) and accel/decel ramp 4
(set in C1-07, C1-08).

8

Baseblock Command (N.O.)

Closed: No drive output

9

Baseblock Command (N.C.)

Open: No drive output

F

Not Used (Through Mode)

Select this setting when the terminal is not used or when using the terminal in the pass-through
mode. The terminal does not trigger a drive function but can be used as digital input for the
controller the drive is connected to.

14

Fault Reset

Closed: Resets faults if the cause is cleared and the Up/Down command is removed.

15

Fast Stop (N.O.)

Closed: Decelerates to stop at the Fast Stop ramp set to C1-09.

16

Motor 2 Selection

Open: Motor 1(E1-

, E3-

)

Closed: Motor 2 (E2-

, E4-

)

17

Fast Stop (N.C.)

Open: Decelerates to stop at the Fast Stop ramp set to C1-09.

18

Timer Function Input

Triggers the timer set up by parameters b4-01 and b4-02. Must be set in conjunction with the
timer function output (H2-

= 12).

1A

Accel/decel Ramp Selection 2

Used in conjunction with an input terminal set for “Accel/decel ramp selection 1” (H1-

= 7),

and allows the drive to switch between accel/decel ramp 3 and 4.

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

Advertising