B parameter table – Yaskawa L1000E AC Drive CIMR-LE†A User Manual

Page 183

Advertising
background image

B Parameter Table

YASKAWA TOEPYAIL1E01A YASKAWA AC Drive L1000E Quick Start Guide

183

Pa

ra

me

te

r T

abl

e

B

H2: Multi-Function Digital Outputs

79

Brake Feedback

Used for brake supervision and detection of incorrect operation.

<1> Motor Contactor Feedback (H1-

= 56) = Normally open (N.O.).

<2> Brake Feedback (H1-

= 79) = Normally open (N.O).

No.(Addr.)

Name

Description

Setting

H2-01

(40BH)

Terminals M1-M2 Function
Selection (relay)

Refer to the table below for a description of setting values.

Default: 50
Min: 0
Max: 161

H2-02

(40CH)

Terminals M3-M4 Function
Selection (relay)

Default: 51
Min: 0
Max: 161

H2-03

(40DH)

Terminals M5-M6 Function
Selection (relay)

Default: 6
Min: 0
Max: 161

H2-04

(40EH)

Terminal P1-C1 Function
Selection (photocoupler)

Default: 37
Min: 0
Max: 161

H2-05

(40FH)

Terminal P2-C2 Function
Selection (photocoupler)

Default: F
Min: 0
Max: 161

H2 Multi-Function Digital Output Settings

H2-

Setting

Function

Description

0

During Run

Closed: An Up/Down command is active or voltage is output.

1

Zero Speed

Open: Output speed is greater than the value of E1-09 (Minimum Output Frequency) or S1-01 (Zero
Speed Level at Stop).
Closed: Output frequency is less than or equal to the value of E1-09 (Minimum Output Frequency)
or S1-01 (Zero Speed Level at Stop).

2

Speed Agree 1

Closed: Output speed equals the speed reference (plus or minus the hysteresis set to L4-02).

3

User-set Speed Agree 1

Closed: Output speed and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).

4

Speed Detection 1

Closed: Output speed is less than or equal to the value in L4-01 with hysteresis determined by L4-02.

5

Speed Detection 2

Closed: Output speed is greater than or equal to the value in L4-01 with hysteresis determined by
L4-02.

6

Drive Ready (READY)

Closed: Power up is complete and the drive is ready to accept an Up/Down command.

7

DC Bus Undervoltage

Closed: DC bus voltage is below the Uv trip level set in L2-05.

8

During Baseblock (N.O.)

Closed: Drive has entered the baseblock state (no output voltage).

H1 Multi-Function Digital Input Settings

H1-

Setting

Function

Description

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_