1. Safety PrecautionS:

Warning: To avoid fire, shock and serious personal injury,

follow all instructions carefully. Read your owner’s manual

carefully before installing the ceiling fan control. Retain

owner’s manual for future reference.

2. To avoid possible electrical shock, be sure electricity is

turned off at the main fuse box or circuit breaker panel

before wiring.

3. This control is designed to operate only one ceiling fan.

note: This fan slider control is rated for 1.25 amps at

120 volts. If your ceiling fan is equipped with a variable

speed pull chain switch control, make sure to set it

at the highest speed before installing the fan slider control.

This will avoid erratic speeds and possible damage to

your ceiling fan.

4. Make certain no bare wires are exposed outside the connectors.
5. All wiring must conform to National and Local Electrical

Codes. If you feel you do not have enough electrical

wiring knowledge or experience, have your fan/light

dual slider control installed by a licensed electrician.

Any electrical work not described in this manual should be

performed by a licensed electrician.

6. Use of this control with some ceiling fans could result in

fire, shock and serious personal injury. Use this fan control

only with capacitor speed controlled ceiling fans.

inStallation

note: Installation of this control requires that the three-con-
ductor cable with ground wire be run between the control wall
box and the ceiling fan outlet.
1. After electricity has been turned off at the main fuse box or

circuit breaker panel, remove the existing wall plate and

switch.

2. Proceed to make the wire connections as follows; (make

sure the fan and light slide switches of the wall control are

set in the “OFF” position ). Connect the solid black wire

from the wall control the black wire from the fan. Connect

the blue wire from the dual slider control to the red

or blue wire from the fan. Connect the black with the

stripe wire from the wall control to the 120v AC hot wire.

Use wire connectors provided to secure the connections.

note: If your outlet box has a ground wire (green or bare
copper), connect the wall transmitter’s ground wire to the outlet
box ground wire. If your outlet box does not have a ground wire,
connect the wall transmitter’s ground wire directly to one of the
screws from the outlet box.
note: Refer to schematic on back of wall control.
3. Secure the dual slider control to the outlet box using the

two 6-32” x 3/4” screws provided.

4. Secure the face plate over the dual slider control with the

two 6-32” x 1/4” screws provided.

inStallation and oPerating inStructionS

for fan/light dual Slider control

Warning!

Shut PoWer off at fuSe or circuit breaker.

6-32" x 3/4"

SCREWS

6-32" x 1/4"

SCREWS

BLACK

BLACK

BLUE

BLUE

BLACK

BLACK

WHITE

AC 120V

INPUT

BLACK

WHITE

WHITE

GREEN

TO GROUND

BLA

CK/

WHITE

BLA

CK

BLA

CK

FAN

FIG. 1

Warning!

hook uP “in SerieS” only

Do not connect to hot and common wire of electric circuit
or switch will be damaged. Refer to Fig. 1.

Date Issued: 8/8/08

IS-337010-US

BLA

CK/

WHITE

BLUE

BLUE

GREEN

TO

GR

OUND

BLACK

Advertising