11-PROBLEMS/CAUSES/SOLUTIONS
The product always runs at maximum
power when in automatic mode.
The room thermostat is in the maximum
position.
Set the thermostat temperature.
Faulty temperature probe.
Check the probe and replace it, if necessary.
Faulty or malfunctioning control panel.
Check the panel and replace it, if necessary.
Thermostat is set to minimum.
Set the thermostat temperature.
The appliance does not go on.
No power supply.
Check that the plug is inserted and the
main switch is in the “I” position.
Faulty pellet probe.
Wait for the pellet or water tank to cool
down and restart the product.
Fuse blown.
Replace the fuse.
Clogged smoke exhaust or smoke duct.
Clean the smoke exhaust and/or the
smoke duct.
An alarm has been triggered.
Verify the type of alarm and proceed
accordingly.
Check the brazier.
Clean the brazier and remove any deposits
or residues of non-burned pellets.
Check the position of the brazier.
Put the brazier back in its place.
Check that the ignition plug warms up.
Check and if necessary, replace.