RISCO Group Wireless WatchOUT PIR Outdoor User Manual
Page 10

10
Installation Instructions
External Base
Angle Locking
Screw
(See Note 2)
See Detail A
Swivel to External Base
Connecting Screws
Detail A
Swivel Assy
Connecting Screw
(See Note)
Snaps
S1
W1
S2
S3
PCB
Internal Base
Figure 7
NOTE:
Do not open or close the Swivel Assy Screw since it is used for connecting the swivel parts only
(factory tightened).
4.
Secure external base to swivel with two screws fastened trough knockouts S1 and S2
(Figure 7).
5.
Insert the supplied angle locking screw from the external base through the angle locking screw
knockout S3 on the external base to the standard swivel (Figure 7).
6.
Tilt and Rotate the Standard Swivel to the desired position.
Once the Standard Swivel is in the desired position, secure
the angle locking screw.
7.
Line up the internal base onto the external base. Insert
tamper wiring through the internal base.
8.
Secure internal base to external base (Lock I1, Figure 2).
9.
To readjust the Standard Swivel when the PCB is installed
(Figure 8):
a. Bend down the black foam located below the RED LED on
the PCB (enough to reach the Swivel locking screw).
b. Use a Hex screwdriver to release the locking screw (see
Figure 8).
c. Tilt and/or Rotate the Standard Swivel to the desired
position.
d. Secure the angle locking screw.
Figure 8: PCB