Step 3: Set Bus Zone Basic Attributes
Refer to section Programming Zones Attributes to define the zone parameters.

Note:

In the zone designation XY:ZZ the X represent the Bus Expander ID as set by its dip
switches.
Step 4: Programming the Bus Detectors Advanced Parameters

1. From the main Installer menu select [2] Zones > [1] Parameters > [2] By Category >

[7] Advanced > [4] BZ Parameters

.

2. Select the zone number that the bus zone was assigned to and press

.

3. Configure the parameters for the relevant bus detector.

Communication Method

1. From the main installer programming menu: 5) Communication menu > 1) Method.
2. Select each method (PSTN, IP and/or GSM) and define its parameters.

Note:

1. LightSYS’s menus include only those communication modules installed on-board
2. To establish GPRS communication set up the APN (Access Point Name) and Email

according to the details instructed by the cellular provider.

3. For IP communication set to dynamic IP (Quick key



)

Report to Monitoring Station

You can define up to three MS accounts and several associated parameters that define the nature of
communication, event reporting and confirmation between the system and the MS.

1. From the main installer programming menu select 5) Communication menu and select 2) MS.
2. Select the 1) Report type (Voice, SMS, IP/GPRS) for each MS and define its parameters.
3. Select 2) Account number and define an account number for each MS.
4. Select 3) Comm format to define the transmission format, SIA or Contact ID.
5. Go through the menus to program any other parameters for the communication with the

monitoring station.

Follow Me Destinations

Now that you have set up the methods for LightSYS to communicate with the MS and the owner,
you can define the destinations to which event notifications will be sent. Up to 16 follow me
destinations can be defined in the system.

1. From the main installer programming menu: 5) Communication menu > 4) Follow Me.
2. Under 1) Define FM set each destination’s:
Or
1. From your riscocloud log-in (p 21), click: SETTINGS

> Alerts > ADD NEW

2. Enter recipient Name, choose the Alert Language and then the following:

Report Type (Voice (panel only), SMS, Email,)

Partitions: Specify the partitions that will initiate the Follow Me report due to a certain

event that occurred in the assigned partitions

The events that will be sent, organized by category (possibly including Alarms,
Arm/Disarm, Troubles, GSM, Environmental, Miscellaneous)