Pulse Train Application

Output a user-defined pulse train from [PULSE IN/OUT] connector. The specific

parameters to be set in the pulse list as shown in the table below.

SN

On Time

Off Time

Repeat

1

10ms

30ms

2

2

20ms

40ms

1

1. Restore to factory setting

Press System Reset Preset Type “Factory” and then press Preset to
restore the factory setting.

2. Install Pulse Train Generator (Option)

Please refer to

DSG3000 Firmware and Options Installation Instruction

to install

and activate the pulse train generator (option PUG-DSG3000).

3. Edit the Pulse Train List

Press Pulse to use the page up/down key

to open the 3/3 menu page,

and then press Train List to enter the editing interface of pulse train list.


 Insert

If the parameter values in the current list are the only one row, press

Insert to insert a row with the same pulse value below the current row.

 Delete

If the parameter values in the current list are more than two lines, you can

press Delete to delete the pulse value of the row currently selected, and

last retain the only two rows parameters.

 Edit

Use the direction keys or knob to move the cursor and select the

parameters of the first row to be edited.

On Time: use the numeric keyboard to input the value 10, and select

the desired unit (ms) from the pop-up unit menu or unit keys.

Off Time: use the numeric keyboard to input the value 30, and select

the desired unit (ms) from the pop-up unit menu or unit keys.

Repeat: use the numeric keyboard to input the value 2, and then press

Enter softkey or Enter.

Use the same method to set the pulse parameters of the second row.

NOTE:

Dwell time is calculated automatically by the three parameters (On

Time, Off Time and Repeat) to be set.