4-5 CHECKING FUNCTIONAL MEMBERS

(1) STATOR

Disengage connectors on the wires from stator and

check the resistance between the wires using a circuit

tester referring to the table below.

NOTE : If the circuit tester is not sufficiently accurate, it may not show the values given and may give erroneous readings.

Erroneous readings will also occur when there is a wide variation of resistance among coil windings or

when measurement is performed at ambient temperature different from 20 C (68 F).

(2) ROTOR

Measure resistance between the field coil.

NOTE1 : When measuring the field coil resistance, be sure

to disconnect the soldering connection and take

out diode rectifier and surge absorber.

NOTE2 : When measuring, tolerance should be considered

because of the tester inaccuracy, winding number

variation, ambient temperature etc.

(Wire color)

(Black - Blue)

(Red - White)

(Yellow - Yellow)

(Brown - Brown)

Coils

RGX2900

RGX4800

RGX3600

Coil resistance (

)

50Hz-240V 60Hz-120/240V

50Hz-220V
50Hz-230V

60Hz-120/240V

50Hz-220V
50Hz-230V

60Hz-120/240V

50Hz-220V
50Hz-230V

50Hz-240V

50Hz-240V

AC coil 1

AC coil 2

DC coil

0.8

0.6

0.4

0.8

0.6

0.4

2.2

1.3

0.9

0.3

0.2

0.2

0.9

0.9

2.2

0.3

0.6

0.6

1.7

0.2

0.7

0.7

1.3

0.2

0.4

0.4

1.0

0.2

0.4

0.4

0.9

0.2

0.3

0.3

0.6

0.1

Condenser coil

RGX2900

RGX4800

RGX3600

1.8

1.6

1.6

Coil resistance (

)

Field coil

Advertising
This manual is related to the following products: