T1/e1 subsystem configuration, T3/e3 subsystem configuration – Enterasys Networks Security Router X-PeditionTM User Manual

Page 91

Advertising
background image

Features

XSR User’s Guide 4-3

Line rate - 34.368 Mbps

Full rate - 34.0995 Mbps (G751)

Sub-rate - approximately 3 Mbps increments up to 33 Mbps

Compatible DSUs supported

Cisco or Quick Eagle (formerly Digital Link) DL3100 E3 -300-33.920 Kbps

ADC Kentrox T3/E3 IDSU

Scrambling - Cisco mode only

Performance Monitoring Local Network Port Statistics - Per RFC-2496- Current 15-minute, 24-
hour (96 *15-minute intervals) and total for 24 hours

T1/E1 Subsystem Configuration

Each T1/E1 physical port is represented as a T1 or E1 controller. This is valid for both full rate T1/
E1 mode and fractional/channelized modes. Each T1/E1 physical port (line) can be configured to
run in one of the following modes:

Full rate T1/E1 mode - full T1/E1 line bandwidth is used by one user

Fractional T1/E1 mode - only one Channel Group is assigned to one T1/E1 physical line

Channelized T1/E1 mode - more than one Channel Group is assigned to one T1/E1 physical
line

For both fractional and channelized configurations, each configured Channel Group, which might
contain individual timeslots or ranges of timeslots, uses only one of the available logical channels.
All configured T1/E1 lines are recognized by the system software as serial interfaces. That implies
that all of the available configuration procedures for interfaces are applicable. Each of the serial
interfaces can be configured to carry data traffic with PPP encoding.

T3/E3 Subsystem Configuration

Each T3/E3 physical port is represented as a T3 or E3 controller. This is valid for both full and sub-
rate T3/E3 modes. Un-channelized or “unformatted” service creates a point-to-point connection
between your network equipment and that of the service provider. The T3/E3 WAN transmission
line can be provisioned as follows:

Full rate service is covered by national and international standards. Only one data stream at full
data rate is sent over the T3/E3 line.

T3 - 44.2Mbps payload, Framing DS3 ANSI T1.107

E3 - 33.920 Mbps payload, Framing G.751.

The entire bandwidth of the line is used to pass Frame Relay or PPP data. Frame Relay 
service can be provisioned in a number of ways, e.g., measured T3 service provides an 
unlimited (burstable) T3 with charges based on bandwidth used.

Sub-rate service includes no standards. It is provisioned by T3 or E3 DSUs which transmit only
one data stream at a reduced rate. Supported rates are DSU-specific. Data rates are:

T3 - 1 to 35 MHz in 0.5MHz steps

E3 - 1 to 24.5 MHz in 0.5MHz steps

Sub‐rate T3/E3 DSUs include: Digital Link, Kentrox, Adtran, Verilink and Larscom.

Advertising