Amprobe ACDC-620T Clamp-On-Multimeter User Manual
Page 49
Advertising
ELECTRICALSPECIFICATIONS
Accuracy is giveN as ± % of reading + the number of least significant digits at
23
o
C ± 5
o
C, with relative hunidity Less than 80% R.H.
Range
Resolution
Accuracy
Overload
Protection
400V
0.1V
1000v
1V
±(1% rdg + 3 dgt)
1000V
AC RMS
Range
Resolution
Accuracy
Overload
45Hz ~ 400 Hz
Protection
400V
0.1V
1000v
1V
±(1,5% rdg + 3 rdg)
1000V
AC RMS
c
DC VOLTAJE
c
AC Voltage
(TRUERMS: Froml 10% al 100% of range)
●
Input Impedance: 10M
Ω
// less than 100pF.
crest Factor: <3:1
●
Input Impedance: 10M
Ω
.
Range
Resolution
Accuracy
Overload
Protection
400V
0.1V
1000v
1V
±(1% rdg + 3 rdg)
1000 Voltios CA
Eficaces (RMS)
c
VOLTAGE ( 1ms PEAKHOLD)
SPECIFIED ACCURACY+/- 40 Digits for Changes >1ms in duration .
●
Input Impedance: 10M
Ω
.
48
Advertising