Table 5.1

Absolute Maximum Stress Ratings

1

1. Stresses beyond those listed above can damage the device. These are stress ratings only; func-

tional operation of the device at or beyond these values is not implied.

Symbol

Parameter

Min

Max

Unit

Test Conditions

T

STG

Storage temperature

−

40

125

°

C

–

V

DD-Core

Supply voltage

−

0.3

2.2

V

–

V

DD-IO

I/O supply voltage

−

0.3

3.9

V

–

V

IN

Input voltage

−

0.5

V

DD

+ 0.5

V

–

I

LP

2

Latch-up current

±

150

–

mA

−

2 V < V

PIN

< 8 V

T

2

Lead temperature

–

125

°

C

–

ESD

2

2. SCSI pins only.

Electrostatic discharge

–

2000

V

MIL-STD 883C,

Method 3015.7

Table 5.2

Operating Conditions

1

1. Conditions that exceed the operating limits can cause the device to function incorrectly.

Symbol

Parameter

Min

Nominal

Max

Unit

Test Conditions

V

DD-Core

Core and analog supply
voltage

1.71

1.80

1.89

V

–

V

DD-IO

I/O supply voltage

2.97

3.30

3.63

V

–

I

DD-Core

Core and analog supply
current (dynamic)

2

2. Core and analog supply only.

–

1.40

1.70

A

–

I

DD-I/O

I/O supply current
(dynamic)

–

0.40

0.80

A

–

T

j

Junction temperature

–

–

115

°

C

–

T

A

Operating free air

0

–

70.0

°

C

–

θ

JA

Thermal resistance
(junction to ambient air)

–

–

15.0

°

C/W