Table5.14 reset input, Figure5.6 reset input, Reset input – Avago Technologies LSI53C1020 User Manual
Page 130
Advertising

5-10
Specifications
Version 2.4
Copyright © 2001–2004 by LSI Logic Corporation. All rights reserved.
and
provide reset input timing data.
Figure 5.6
Reset Input
Table 5.14
Reset Input
Symbol
Parameter
Min
Max
Unit
t
1
Reset pulse width
10
–
ns
t
2
Reset deasserted setup to CLK HIGH
0
–
ns
t
3
MAD setup time to CLK HIGH (for configuring the MAD bus only)
20
–
ns
t
4
MAD hold time from CLK HIGH (for configuring the MAD bus only)
20
–
ns
t
1
t
2
t
3
t
4
CLK
RST/
MAD*
Note: *When enabled
Valid
Data
Advertising