6.9 Gain Adjustment of Analog Monitor Output (Fn00D)
6-23
6
Utili
ty Fu
ncti
ons (Fn
)
(3) Operating Procedure
Use the following procedure to perform the gain adjustment of analog monitor output.
1.
In the SigmaWin+ main window, click
Setup
-
Adjust Offset
-
Adjust the Analog Monitor
Output
. The
Adjust the Analog Monitor Output
box will appear. Click the
Gain Adjustment
tab.
In the
Channel
box, either CH1 or CH2 can be selected.
2.
To change the value of the gain adjustment, click
+1
(increase) or
-1
(decrease) button.