Yaskawa Σ-V Series AC Servo Drives Rotational Motor MECHATROLINK-III User Manual

Page 265

Advertising
background image

8 Troubleshooting

8.1.2 Troubleshooting of Alarms

8-10

A.860:
Encoder Overheated

(Only when an absolute

encoder is connected.)
(Detected on the encoder

side.)

The ambient operating tempera-

ture around the servomotor is too

high.

Measure the ambient operating tem-

perature around the servomotor.

The ambient operating temperature

must be 40

°

C or less.

The motor load is greater than the

rated load.

Check the accumulated load ratio

(Un009) to see the load.

The motor load must be within the

specified range.

An encoder fault occurred.

Restart the SERVOPACK. If the

alarm still occurs, the servomotor

may be faulty. Replace the servo-

motor.

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the

alarm still occurs, the SERVO-

PACK may be faulty. Replace the

SERVOPACK.

A.b31:
Current Detection

Error 1

The current detection circuit for

phase U is faulty.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-

PACK may be faulty. Replace the
SERVOPACK.

A.b32:
Current Detection

Error 2

The current detection circuit for
phase V is faulty.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.b33:
Current Detection

Error 3

The detection circuit for the cur-
rent is faulty.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

The servomotor main circuit
cable is disconnected.

Check for disconnection of the ser-
vomotor main circuit cable.

Correct the servomotor wiring.

A.b6A:
MECHATROLINK

Communications ASIC

Error 1

SERVOPACK MECHA-
TROLINK communication sec-
tion fault.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.b6b:
MECHATROLINK

Communications ASIC

Error 2

MECHATROLINK data recep-
tion error occurred due to noise
interference.

Take measures against noise. Check
the MECHATROLINK communi-
cations cable and FG wiring and
take measures such as adding ferrite
core on the MECHATROLINK
communications cable.

SERVOPACK MECHA-
TROLINK communication sec-
tion fault.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.bF0:
System Alarm 0

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.bF1:
System Alarm 1

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

A.bF2:
System Alarm 2

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-

PACK may be faulty. Replace the
SERVOPACK.

A.bF3

:

System Alarm 3

A SERVOPACK fault occurred.

Restart the SERVOPACK. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

Advertising