Control Codes

Viewing control state (Get control command)

Header

Command

ID

Data length

Checksum

0xAA

Command type

0

Controlling (Set control command)

Header

Command

ID

Data length

Data

Checksum

0xAA

Command type

1

Value

Command

No.

Command type

Command

Value range

1

Power control

0x11

0~1

2

Input source control

0x14

-

3

Screen mode control

0x18

-

4

Safety Lock

0x5D

0~1

All communications take place in hexadecimals. The checksum is calculated by adding up

all values except the header. If a checksum adds up to be more than 2 digits as shown below

(11+FF+01+01=112), the first digit is removed.

E.g. Power On & ID=0

Header

Command

ID

Data length

Data 1

Checksum

0xAA

0x11

1

"Power"

Header

Command

ID

Data length

Data 1

12

0xAA

0x11

1

1

To control all devices connected by a serial cable simultaneously irrespective of IDs, set the

ID as "0xFE" and transmit commands. Commands will be executed by each device but ACK

will not respond.