Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. o • 1/13

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances to combustibles as specified. Framing or finishing

material closer than the minimums listed must be construct-

ed entirely of noncombustible materials (i.e., steel studs,

concrete board, etc).

Figure 5.3 Clearances To Combustible Mantels Or Other

Combustibles Above Appliance

Mantels (Combustible/Non-Combustible)

Figure 5.4 Non-Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

UNLIMITED

TOP VIEW

7 in.

(180 mm)

3 in.

(80 mm)

MIN.

FRAMING

1-1/4 in. (30 mm)

3/8 in. (10 mm) BUILDING MATERIAL

1-1/2 in. (37 mm)

Front Side Finishing Detail

Figure 5.5 Front Side Finishing Detail

14 in.

(360 mm)

MIN.

11-3/4 in. (300 mm)

MAX.

3/8 in. (10 mm)

Thick Wall

Sheathing

MEASUREMENT

FROM TOP OF

FIREPLACE

OPENING

Note: For non-combustible fireplace finish material (marble,

stone, etc) specifications refer to Section 13.C.

Mantel Leg (Combustible/Non-Combustible)

3/8 in. (10 mm)

THICKWALL SHEATHING

3-1/2 in. (89 mm)

1 in. (25 mm)

AIR SPACE

NON-COMBUSTIBLE

BOARD SHIPPED

WITH APPLIANCE

1 in. (25 mm)

Figure 5.6 Non-Combustible Zone

Note: AIR SPACE denoted in Figure 5.6 is defined by the

nailing tabs and metal standoffs.