Heat & Glo Fireplace HEAT & GLOW XLR-N-AU User Manual
Page 26
Advertising

Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. o • 1/13
26
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
Figure 7.4
1. Top Vent - Horizontal Termination - (continued)
Top Vent - Horizontal Termination
Venting with 2 elbows
Note: Use SLP Series
components only.
V Minimum
H
1
+ H
2
Maximum
90 Elbow
1-1/2 ft. (457 mm)
1 ft. (305 mm)
3 ft. (914 mm)
1-1/2 ft. (457 mm)
3-1/2 ft. (1067 mm)
2 ft. (610 mm)
5 ft. (1.52 m)
2.5 ft. (762 mm)
6 ft. (1.85 m)
3 ft. (914 mm)
7 ft. (2.13 m)
3.5 ft. (1066 mm)
10 ft. (3.05 m)
4 ft. (1.2 m)
15 ft. (4.6 m)
H + H
1
Max. = 15 ft. (4.6 m)
V + H + H
1
Max. = 40 ft. (12.2 m)