G. air shutter setting, H. media options, I. verify performance of appliance – Heat & Glo Fireplace HEAT & GLOW XLR-N-AU User Manual

Page 54

Advertising
background image

Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. o • 1/13

54

Figure 14.2 Air Shutter

G. Air Shutter Setting

Air shutter settings may be adjusted by a qualified install-

er at the time of installation. The air shutter is set at the

factory for minimum vertical vent run. Adjust air shutter for

longer vertical runs. See Figure 14.2.
• Loosen the 1/4 in. (6 mm) screw.
• Twist shutter to adjust
• Shutter may be open for longer horizontal vent runs.
• Do not close the air shutter more than 5/8 in. (16 mm)

for NG or 3-1/8 in. (80 mm) for LP. Note: the air shutter

should be fully open when using butane.

• Tighten the screw.
NOTICE: If the flames appear to be orange, open the air

shutter to prevent residue buildup on the glass.

H. Media Options

Unit ships without a media option. Available approved

media options are:
• MEDIA-AMBER
• MEDIA-BLACK
• MEDIA-CLEAR
• MEDIA-COBALT
• MEDIA-BK2-GEMS
• MEDIA-WH2-GEMS
• MEDIA-GEMS
• PORC-BASE
• XLR-LOGS
• MEDIA-STONES-2

I. Verify Performance of Appliance

1. Verify pilot sparks, pilot lights, pilot stops sparking, and

the main burner turns “ON” by turning wall control “ON”.

2. Turn fireplace OFF. Verify that the both the pilot and

burner turn “OFF”.

3. Repeat Step 1 above.
4. With the burner “ON” remove the green wire connected

to the gas valve after the second audible “beep” from

the control module is heard. The main burner should

shut off. Turn appliance “OFF”.

5. Reattach the green wire to the valve and turn ON the

fireplace. The main burner should light after the second

audible “beep” from the control module is heard.

6. With the main burner ON, remove the green wire con-

nected to the gas valve after the second audible “beep”

from the control module is heard. The main burner

should shut off.

7. Turn fireplace “OFF” and reattach orange wire to the

valve.

Shutter Settings - Glass Media and Media-Stones-2

USA/Canada Europe

AU

NZ

NG

1/16 in.

.2 cm

2 mm

2 mm

LP (Propane)

5/16 in.

.8 cm

8 mm

8 mm

Butane*

N/A

Full Open Full Open Full Open

*Butane gas is only approved for use in Europe, Australia,

and New Zealand

Shutter Settings - XLR Logs

USA/Canada Europe

AU

NZ

NG

3/16 in.

.5 cm

5 mm

7 mm

LP (Propane)

7/16 in.

1.1 cm

11 mm

11 mm

Butane*

N/A

Full Open Full Open Full Open

*Butane gas is only approved for use in Europe, Australia,

and New Zealand