C. vent components diagrams (continued) – Heat & Glo Fireplace HEAT & GLOW XLR-N-AU User Manual

Page 64

Advertising
background image

Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. o • 1/13

64

9 in.

(222 mm)

6-1/2 in.

(165 mm)

6-1/2 in.

(168 mm)

6 in.

(152 mm)

6-1/2 in.

(165 mm)

6-1/2 in.

(168 mm)

10-1/4 in.

(251 mm)

6-1/2 in.

(165 mm)

9-1/4 in.

(235 mm)

SLP-45 - 45° Elbow

SLP90- 90° Elbow

Effective

Height/

Length

SLP-PIPE

SLP-HVS

Horizontal Pipe

Support

SLP-FS

Ceiling Firestop

SLP-WS

Wall Shield Firestop

C. Vent Components Diagrams (continued)

Figure 17.5 SLP Series Vent Components

26 in.

(660 mm)

DVP-HSM-B

Extended Heat Shield

Effective Height/Length

Pipe

in.

mm

SLP4

4

102

SLP6

6

152

SLP12

12

305

SLP24

24

610

SLP36

36

914

SLP48

48

1219

SLP6A

2 - 6

51 - 152

SLP12A

2 - 12 51 - 305

Advertising