B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances to combustibles as specified. Framing closer than the

minimums listed must be constructed entirely of noncom-

bustible materials (i.e., steel studs, concrete board, etc.)

Failure to comply could cause fire.

Note: For non-combustible fireplace finish material (marble,

stone, etc) specifications refer to Section 13.C.

Figure 13.7 Clearances To Combustible Mantels Or Other

Combustibles Above Appliance

Mantels (Combustible/Non-Combustible)

Figure 13.8 Non-Combustible Mantel Leg or Wall

Projections

(Acceptable on both sides of opening)

UNLIMITED

TOP VIEW

7 in.

(180 mm)

3 in.

(80 mm)

MIN.

FRAMING

1-1/4 in. (30 mm)

3/8 in. (10 mm) BUILDING MATERIAL

1-1/2 in. (37 mm)

Front Side Finishing Detail

Figure 13.9 Front Side Finishing Detail

14 in.

(360 mm)

MIN.

11-3/4 in. (300 mm)

MAX.

3/8 in. (10 mm)

Thick Wall

Sheathing

MEASUREMENT

FROM TOP OF

FIREPLACE

OPENING

Note: For non-combustible fireplace finish material (marble,

stone, etc) specifications refer to Section 13.C.

Mantel Leg (Combustible/Non-Combustible)