Heat & Glo • SLR-B • 2195-900 Rev. P • 12/11

28

Figure 7.7

1. Top Vent - Horizontal Termination - (continued)

Top Vent - Horizontal Termination

Venting with 3 elbows

Note: Use SLP Series

components only.

V

1

H

1

H

3

H

2

INSTALLED

HORIZONTALLY

INSTALLED

HORIZONTALLY

Note: There MUST be a 25%

reduction in total H when using

fl ex vent except when using the

simple up and out installation

(see Figure 7.3).

V Minimum

H

1

+ H

2

+ H

3

MAXIMUM

SLR-B (NG ONLY)

3 ft.

914 mm

15 ft.

4.6 m

H

1

+ H

2

+ H

3

MAX. = 15 ft. (4.6 m)

V

1

MAX. = 7 ft (2.1 m)

CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS

termination caps are not approved for use with pro-

pane (LP) fuel. May lead to elevated glass temper-

ature that may cause tempered glass breakage.