Non-Combustible Finish Materials

0 - 1 inch thickness-Overlap Fit Method
Both the Tonic and Martini decorative fronts are designed

to overlap fi nish materials 0 inches to 1 inch thick. See

Figure 13.9.
NOTICE: This one inch maximum not only includes the

decorative fi nish materials (marble, tile, slate, etc) but

also the mortar or adhesive used to attach the decorative

fi nish material.
The non-combustible fi nish material can be installed up to

the fi replace opening.

Figure 13.9 Overlap Fit Method (Tonic or Martini Decorative

Front)

FACTORY-INSTALLED

NON-COMBUSTIBLE BOARD

DRYWALL OR

EQUIVALENT (1/2 IN.)

NON-COMBUSTIBLE

FINISHING MATERIAL

0 - 1 IN. THICK

NON-COMBUSTIBLE

FINISHING MATERIAL

0 - 1 IN. THICK

TONIC DECORATIVE

FRONT SHOWN

1-1/2 IN. ABOVE STANDOFF

Overlap Requirement: See Figure 13.9.
Inside Fit requirement: See Figure 13.10 and Figure 13.11.

C. Facing Material

• Facing and/or fi nishing materials must not interfere with

air fl ow through louvers, operation of louvers or doors,

or access for service.

• Facing and/or fi nishing materials must never overhang

into the glass opening.

• Observe all clearances when applying combustible

materials.

WARNING! Risk of Fire! DO NOT apply combustible

materials beyond the minimum clearances. Comply with

all minimum clearances to combustibles as specifi ed in

this manual. Overlapping materials could ignite and will

interfere with proper operation of doors and louvers.
WARNING! Risk of Fire! DO NOT install drywall or other

combustible materials over the factory-installed non-com-

bustible board. Overlapping materials could ignite.
Decorative facing material thickness is measured from

the face of the factory-installed non-combustible board.