A. Framing and Finishing Instructions

WARNING! Risk of Fire! Comply with all minimum clear-

ances to combustibles as specifi ed. Framing closer than the

minimums listed must be constructed entirely of noncom-

bustible materials (i.e., steel studs, concrete board, etc.)
Finishing Instructions

It is important to follow the framing and fi nishing instruc-

tions to ensure proper placement of fi replace into the sur-

rounding framing/fi nishing materials.

Wall sheathing materials 1/2 in. thick are specifi ed in

this installation manual to properly align with the factory-

installed non combustible material.
WARNING! Risk of Fire! DO NOT remove the factory-

installed non-combustible board or cover it with combus-

tible material, such as:

• Drywall (gypsum board)
• Plywood
• Materials that do not meet the ASTM E 136 Non-com-

bustibility standard (below).

Removal of factory-installed, non-combustible board and/

or use of materials not meeting the ASTM E 136 standard

may cause fi re.

Non-Combustible Materials Specifi cation

Material which will not ignite and burn. Such materials are

those consisting entirely of steel, iron, brick, tile, concrete,

slate, glass or plasters, or any combination thereof.

Materials that are reported as passing

ASTM E 136,

Standard Test Method for Behavior of Materials in a

Vertical Tube Furnace at 750 ºC and UL763 shall be

considered non-combustible materials.

Setting the Fireplace into the Framing

Unlike many traditional, single-sided Heat & Glo fi replaces,

this fi replace is recessed into surround framing. The left

and right nailing tabs were designed for the SLR-B model

as a means to ensure the fi replace is recessed to the

correct location within the framing materials.
1. Bend two nailing tabs away from fi replace 180 degrees

on both left and right nailing tabs. Do not adjust the

column standoffs. See Figure 13.1.

2. Screw each nailing tab to the adjoining framing mate-

rial. Ensure that the 1” air space clearance is main-

tained on the sides of the fi replace. See Figure 13.2.

Figure 13.1 Nailing Tabs Installation Position

NAILING

TABS

FACTORY-INSTALLED

NON-COMBUSTIBLE BOARD

Figure 13.2 Front Side Finishing Detail

1 IN.

FRAMING

1/2 IN. FACTORY-SUPPLIED

NON-COMBUSTIBLE BOARD

NAILING TAB

Advertising