Heat & Glo • SLR-B • 2195-900 Rev. P • 12/11

51

WARNING! Risk of Fire! Maintain specifi ed air space

clearances to combustibles.

Failure to comply with these instructions may cause a

fi re or cause the appliance to overheat.

FACTORY-INSTALLED

NON-COMBUSTIBLE BOARD

LOWER COVER PANEL

= NO SCREWS ALLOWED

= 1 INCH. MAX. SELF-TAPPING SCREWS ALLOWED

= 5 INCH - 7 INCH SELF-TAPPING SCREWS ALLOWED

PILOT HOLES (11 LOCATIONS) TO ATTACH

NON-COMBUSTIBLE BOARD TO FRAMING

Figure 13.3 Finishing Details

CAUTION! Risk of Glass Damage and Cuts! DO NOT

drill or install any type of screw or fastener into the lower

cover panel. Sharp screw or fastener tips may penetrate

and break the glass or cause cuts.

The SLR-B must be fi nished using either the Tonic or

Martini decorative fronts. See Figures 13.12 and 13.13.

The fi nal fi replace installation can be accomplished by

either the Overlap Fit or Inside Fit method. Reference

Section 13.C regarding installation details associated

with the Inside Fit and Overlap Fit methods.
It is acceptable to pre-drill holes and use self-tapped

screws in the factory-installed non-combustible board to

attach non-combustible backer board for tile, marble, etc.

Refer to Figure 13.3 for acceptable screw location and

screw length requirements.
Self-tapping screws up to one inch long can be installed

through the nailing tab and outer 3 inch edges of the

factory-installed non-combustible board to secure the

drywall adjacent to the factory-installed non-combustible

board. See Figure 13.3.

Note: It is acceptable to use a silicone sealant with a

minimum of 300ºF continuous exposure rating to adhere

drywall to lower cover panel.

Note: Refer to Section 13.C regarding installation details

associated with the Inside and Overlap Fit methods.

Do not drill or install screws which may penetrate the

lower cover panel as this will restrict required access

to the glass, battery-back-up, and remote receiver. See

Figure 13.3.
The appliance is designed to accept 1/2 in. wall sheathing

materials such as drywall, plywood, wood composites, or

non-combustible materials. The type of material used

depends whether the installation is an Inside or Overlap

Fit Method. Refer to Section 13.C regarding installation

details associated with the Inside and Overlap Fit methods

The factory-supplied non-combustible board must be

used in all installations. It must be directly attached to

structural framing adjacent to the appliance. Screw fas-

teners should be installed in the pilot holes provided in

the outer perimeter of the non-combustible board. See

Figure 13.3.
The factory-supplied board is designed such that its edg-

es will be at the approximate center of the adjacent fram-

ing, assuming it is 1-1/2 in. nominal thickness. This will

allow the wallboard joints to occur on the center of the

framing where the panels can be fastened properly. If the

framing thickness is less than 1-1/2 in. nominal, such as

with formed steel systems, then it may be necessary to

adjust the adjacent framing dimensions so that the non-

combustible board and wallboard joints are centered on

the framing.