B. mantel and wall projections – Heat & Glo Fireplace HEAT & GLO SLR-B (COSMO) User Manual

Page 53

Advertising
background image

Heat & Glo • SLR-B • 2195-900 Rev. P • 12/11

53

B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances to combustibles as specifi ed. Framing closer than the

minimums listed must be constructed entirely of noncom-

bustible materials (i.e., steel studs, concrete board, etc.)

Failure to comply could cause fi re.

Figure 13.5 Clearances To Combustibles Mantels Or Other

Combustibles Above Appliance

Combustible Mantels

Non-combustible Mantels

Figure 13.6 Clearances To Non-Combustible Mantels Or Othe

Non-Combustibles Above Appliance

Figure 13.7 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Figure 13.8 Non-Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Combustible Mantel Legs Or Wall Projections

Extending Past The Face Of The Fireplace

Non-combustible Mantel Legs Or Wall Projections

Extending Past The Face Of The Fireplace

3 FT. MAXIMUM

6 IN.

MINIMUM

2 IN.

MINIMUM

FIREPLACE

OPENING

3 IN.

MINIMUM

UNLIMITED

7 IN.

FIREPLACE

OPENING

14 IN.

MIN.

12 IN.

MAX.

1/2 IN.

Thick Wall

Sheathing

MEASUREMENT

FROM TOP OF

FIREPLACE

OPENING

Note: For non-combustible fi replace fi nish material (marble,

stone, etc) specifi cations refer to Section 13.C.

14 IN.

MIN.

12 IN.

MAX.

1/2 IN.

Thick Wall

Sheathing

MEASUREMENT

FROM TOP OF

FIREPLACE

OPENING

4 IN.

MAX.

1 IN.MIN.

Advertising