Heat & Glo • SLR-B • 2195-900 Rev. P • 12/11

55

Non-Combustible Finish Material 0-4 Inches Thick

Bottom Joint

3/4 IN.

3/4 IN.

3 IN.

Figure 13.11 Noncombustible Surface Finishing Material 0-4 Inch

Thick-Inside Fit Method (Tonic Decorative Front

Only)

FACTORY-INSTALLED

NON-COMBUSTIBLE

BOARD

DRYWALL OR

EQUIVALENT

(1/2 IN.)

20-1/2 IN. APPLIANCE

OPENING (HEIGHT)

3/4 IN.

3 IN.

0 - 4 IN.

0 - 4 IN.

Figure 13.10 Inside Fit Method (Tonic Decorative Front Only)

Non-Combustible Finish Materials

0 Inches to 4 Inches Thick Inside Fit Method
The Tonic decorative front is approved for inside fi t ap-

plications. Non-combustible fi nishing materials up to 4

inches thick can be installed around the front (left, right,

top, and bottom).
For the Tonic decorative front inside fi t applications, the

decorative front must be installed tight to the fi nishing

fl anges and must not overlap any fi nish material.
Ensure that minimum clearances to non-combustible fi n-

ish materials meet the specifi cations in Figure 13.11.