2-7. WATER VALVE

4. Check across terminals of the water valve with an ohmmeter.

(Continued)

The meter reading should be 600-650, if reading is not correct
replace the water valve by continuing with this procedure.

5. Remove the electrical wires from the water valve.

6. Disconnect water line.

7. Remove the nut from the bulkhead. This is inside the water pan.

Step 7

8. The water valve assembly can now be removed from the

cabinet.

9. Remove the reducer nipple and bulkhead from the water valve.

10. Remove the reducer nipple, water strainer and elbow as one

piece.

Step 9

11. Remove the remaining elbow from the water valve.

12. Reassemble a new valve in reverse order.

13. Turn on the water supply and check for leaks.

14. Replace the end panel.

15. Turn on the power supply at the breaker box.

Step 10