Henny Penny CW-114 User Manual

Page 14

Advertising
background image

Model CW-216/CW-114

2-8. FLOAT SWITCH

1. Remove electrical power supplied to the cabinet.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

2. Drain the water pan by removing the drain standpipe.

3. Remove the control side end panel.

4. Cut float switch wires just behind the switch.

5. From inside end channel, remove nylon fitting by unscrewing

Step 6

from the switch.

6. Remove float switch.

7. Install a new float switch in reverse order. Make sure float

switch is located in the center of the hole and silicone washer is
positioned properly.

Tighten nut to snug only. Maximum torque not to exceed 3 ft.
pounds.

2-6

103

Advertising
This manual is related to the following products: