Model CW-216/CW-114

PROBLEM

CAUSE

CORRECTION

HEATING SECTION

A. Water will

not heat

B. Water will not

reach desired
temperature

• Replace contactor per Contactor Section

• Check thermostat per Thermostat Section

• Check high limit switch per

High Limit Switch Section

• Faulty contactor

• Faulty thermostat

• Faulty high limit switch

• Low or improper voltage

• Faulty water heating element

• Wiring

• Pans are not over water

• Use a meter and check wall

voltage versus data plate

• Check heating elements per Water Pan

Heater Section

• Check for loose connections or

faulty wires and correct or
replace as necessary

• Place pans over water

C. Radiant heat

not working

• Faulty infinite regulator

• Faulty power switch

• Faulty radiant heater

• Replace infinite regulator per

Infinite Switch Section

• Check power switch, per

Power Switch Section

• Check heater per Radiant Heater Section

1-4