2-18. WATER PAN HEATER
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the heater cover plates.
3. Remove the heater wires from the wire nuts. Check across
the wire of each heater with an ohmmeter. Each heater
should have a reading of 42 ohms for 208 volts and 52 ohms
for 230 volts. If a heater checks defective, replace it by
continuing with this procedure.
4. Using pliers or vise grips, pull the heater from the unit.
5. Install the new heater in reverse order.
6. Replace the heater cover plates.
7. Turn on the power at the breaker box.
2-19. RADIANT HEATER
1. Remove electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the four screws located at the bottom of the heater
housing - two on each end.
803