PROBLEM

CAUSE

CORRECTION

THERMOMETER

A. Reading does

not match
actual
temperature

A. Product not

holding
temperature

• Faulty thermometer

• Insert bulb in block

• Replace per Thermometer Section

• Thermometer bulb is not in

holding block

OPERATIONS

• Doors are not kept closed

• Keep doors closed when possible

• Product held too long

1-2

103

• Water temperature too low

• Radiant heat too low

• Radiant heat not working

• Light bulbs out

• Only hold product for recommended

times

• Check water heating system per

Water Pan Heater Section

• Turn to higher setting

• Check radiant heat system per

Radiant Heater Section

• Replace as required, per

Light Bulb Section

B. Doors are

fogging

• Doors left open too much

allowing doors to cool and
cause condensation

• Radiant heat not high enough

• Radiant heat not working

• Water temperature too high

• Keep doors closed when

possible

• Turn to higher setting

• Check radiant heater per

Radiant Heater Section

• See recommended settings

and temperature

1-3. TROUBLESHOOTING (Continued)