Henny Penny CW-114 User Manual
Page 19
![background image](/manuals/90052/19/background.png)
Model CW-216/CW-114
2-14. INDICATING LIGHT
5. Install a new light by pushing the light through the control
(Continued)
panel until the light snaps securely in the panel.
6. Strip the wires and reconnect with wire nuts.
7. Replace the end panel.
8. Turn on the power supply at the breaker box.
2-15. THERMOMETER
1. Remove the electrical power supplied to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control side end panel.
Step 3
3. Remove the sensor bulb by removing bulb retainer and
pulling on the capillary tube.
4. Remove the nuts holding the mounting brackets on the back
of the thermometer housing. Push the thermometer through
the control panel.
5. Install a new thermometer in reverse order.
6. Replace the end panel.
7. Turn on the power at the breaker box.
Step 4
103
2-11