1 setting methods of baud rate and node id, 1 setting method of canopen baud rate, 2 setting method of canopen node – Hitachi SJ2-CO User Manual

Page 13: Dr node id, Chapter4 setting

Advertising
background image

CHAPTER4 SETTING

9

4.1 Setting methods of Baud rate and Node ID

Follow the procedure below to set Baud rate in CANopen and Node ID, reset the power supply after

changing the setting (setting will be reflected after resetting power supply.). Initial Baud rate: 125kbps,

Initial Node ID: 2.

4.1.1 Setting method of CANopen Baud rate

The table below is setting method of Baud rate with Dip switch.

Baud rate

(kbps)

Dip switch

Setting

Note

Baud rate

(kbps)

Dip switch

Setting

Note

10

250

25

500

50

For

bus

length
greater than
1km bridge
or repeater
device may
be needed

.

800

125

1000

4.1.2 Setting method of CANopen Node

Figure left describes the direction of Dip Switches. See below

ON: 1  OFF: 0

Bit increases from right to left switches. Figure formula below.

NODE ID = NA64*2

6

+ NA32*2

5

+ NA16*2

4

+ NA08*2

3

+ NA04*2

2

+ NA02*2

1

+ NA01*2

0

NA64

NA16

NA32

NA08 NA04 NA02 NA01

DR

NODE ID

ON

OFF

1-9 = OFF, 10=ON:

NODE ID = 1

OFF

ON

2

O

F

F

2

O

F

F

2

O

F

F

2

O

F

F

2

O

F

F

2

O

F

F

2

O

F

F

2

O

F

F

1=OFF 2=ON 3=ON

Advertising