CHAPTER5 CANOPEN COMMUNICATION FUNCTION

20

5.1.16 modes_of_operation (Index: 6060h/6061h)

The actual mode is reflected in the modes of operation display (index 6061h), and not in the mode

of operation(index 6060h). But CANopen Interface Option supported only Velocity Mode. These

objects are always stored “2(Velocity mode)”.

5.2 Keypad display(OPTIONAL OPERATOR:OPE-SRMINI)

In status of initializing CANopen option, the keypad shows following display.

Note: This display appears during initializing which is follow conditions;

Initializing with b084

Trip reset

CANopen option initializing when power is lunched.

“RS” terminal is lunched up.

Occurring un-expected matter.

Black:Segment is “ON”