Chapter7 communication objects lists – Hitachi SJ2-CO User Manual

Page 32

Advertising
background image

CHAPTER7 COMMUNICATION OBJECTS LISTS

28

INDEX

Parameter

Function Name

Size

Unit

Note

0x2691

b091

Stop mode selection

1

-

0x2692

b092

Cooling fan control

1

-

0x2695

b095

BRD selection

1

-

0x2696

b096

BRD ON level

2

1.V

0x26D0

b130

OV LAD STOP selection

1

-

0x26D1

b131

OVLAD STOP level

2

1.V

0x26E0

b140

Over current prevention

1

-

0x26F0

b150

Carrier Mode

1

-

0x2801

C001

Intelligent terminal 1 function setting

1

-

*1

0x2901

C201

Intelligent terminal 1 function setting,2nd motor

1

-

*1

0x2802

C002

Intelligent terminal 2 function setting

1

-

*1

0x2902

C202

Intelligent terminal 2 function setting,2nd motor

1

-

*1

0x2803

C003

Intelligent terminal 3 function setting

1

-

*1

0x2903

C203

Intelligent terminal 3 function setting,2nd motor

1

-

*1

0x2804

C004

Intelligent terminal 4 function setting

1

-

*1

0x2904

C204

Intelligent terminal 4 function setting,2nd motor

1

-

*1

0x2805

C005

Intelligent terminal 5 function setting

1

-

*1

0x2905

C205

Intelligent terminal 5 function setting,2nd motor

1

-

*1

0x2806

C006

Intelligent terminal 6 function setting

1

-

*1

0x2906

C206

Intelligent terminal 6 function setting,2nd motor

1

-

*1

0x2811

C011

Intelligent terminal 1 active state

1

-

0x2812

C012

Intelligent terminal 2 active state

1

-

0x2813

C013

Intelligent terminal 3 active state

1

-

0x2814

C014

Intelligent terminal 4 active state

1

-

0x2815

C015

Intelligent terminal 5 active state

1

-

0x2816

C016

Intelligent terminal 6 active state

1

-

0x2821

C021

Intelligent output 11 setting

1

-

0x2822

C022

Intelligent output 12 setting

1

-

0x2826

C026

Alarm relay output

1

-

0x2828

C028

AM selection

1

-

0x2831

C031

Terminal 11 active state

1

-

0x2832

C032

Terminal 12 active state

1

-

0x2836

C036

Alarm relay active state

1

-

0x2841

C041

Overload advance notice level

2

0.01%

0x2941

C241

Overload advance notice level,2nd motor

2

0.01%

0x2842

C042

Frequency arrival setting for acceleration.

2

0.1Hz

0x2843

C043

Arrival frequency setting for deceleration.

2

0.1Hz

0x2844

C044

PID deviation level setting

2

0.1Hz

0x2852

C052

PID feedback High-LIM

2

0.1Hz

0x2853

C053

PID feedback Low-LIM

2

0.1Hz

0x2871

C071

Communicating transmission speed

1

-

0x2872

C072

Communication code

1

1.Node

0x2874

C074

Communication parity

1

-

0x2875

C075

Communication stop bit

1

-

0x2876

C076

Comm. Error select

1

-

Note *1: Please transmit twice continuously at the change of the value of C001 to C006.

Advertising