I. control module operation – Heat & Glo Fireplace XLR-N-CE User Manual

Page 10

Advertising
background image

Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13

10

I. Control Module Operation

1. The control module has an ON/OFF/REMOTE selector

switch that must be set. See Figure 2.3.

OFF Position: Appliance will ignore all power inputs and

will not respond to any commands from a wall switch or

optional remote. The unit should be in the OFF position

during installation, service, battery installation, , fuel

conversion, and in the event that the control goes into

LOCK-OUT mode as a result of an error code.

ON Position: Appliance will ignite and run continuously

in the HI flame setting, with no adjustment in flame

output. This mode of operation is primarily used for

initial installation or power outage operation with battery

backup.

REMOTE Position: Appliance will initiate commands

from a wired wall switch and/or one of the optional

wireless remote options.

2. A wall switch can be wired into the control module brown

and red wires. See Figure 12.1.

3. The control module has safety feature that automatically

shuts down the fireplace after 9 hours of continuous

operation without receiving a command from the wall

switch or optional remote.

4. If you intend to use both a wired wall switch and an optional

remote control to operate your fireplace, the wall switch

will override any commands given by the remote.

Figure 2.3 Control Module

NG/LP GAS-TYPE

SELECTOR SWITCH

SELECTOR

SWITCH

FLAME HI/LOW

SWITCH

STATUS

INDICATOR LED

MODULE

Note: The HI/LO and LP/NG switches on the control module

are non-functional on the XLR fireplace.

5.

Module Reset Switch

This module may lock-out under certain conditions.

When this occurs, the appliance will not ignite or

respond to commands. The module will go into lock-out

mode by emitting three audible beeps, then continuously

displaying an error code at its status indicator LED.

• Check battery tray. Remove batteries if installed.

Batteries should only be installed for use during power

outages. See Section H.

• Locate the module reset switch. See Figure 2.4 or 2.5.
• Set the module reset switch to the RESET position.
• Wait five (5) minutes to allow possible accumulated gas

to clear.

• Set the module reset switch to ON.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-

ule reset switch more than one time within a five minute

time period. Gas may accumulate in firebox. Call a quali-

fied service technician.

Figure 2.4 Location of Module Reset Switch - Tonic Front

MODULE RESET

SWITCH

Figure 2.5 Location of Module Reset Switch - Martini Front

MODULE RESET

SWITCH

Nine Hour Safety Shutdown Feature

This appliance has a safety feature that automatically

shuts down the fireplace after nine hours of continuous

operation with receiving a command from the wall

switch or optional remote.