D. Electrical Service and Repair

WARNING! Risk of Shock! Label all wires prior to dis-

connection when servicing controls. Wiring errors can

cause improper and dangerous operation. Verify proper

operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with

type 105° C rated wire. Wire must have high temperature

insulation.

E. Junction Cord Information

The junction cord is installed at the factory. Refer to Figure

12.2 and 12.3. for more information.

Note: There is an alternative access to the junction cord.

This can be accessed by removing the valve assembly. See

Figures 11.1 and 11.2.

Figure 12.2. Junction Cord Information

BLUE

BROWN

GREEN/

YELLOW

Figure 12.3 Blower Circuit

240V BLOWER

JUNCTION CORD

AUX 300 CE

GROUND TERMINAL TO

FIREPLACE CHASSIS

COUNTRY OF

DESTINATION PLUG

OPTIONAL

F. Blower

An optional fan and auxilliary box are available for this

appliance. Refer to instructions provided with GFK-240V

fan kit.
Use of the fan requires that the Junction cord (factory in-

stalled) be connected to 220/240 VAC service before per-

manently enclosing the heater. The service cord is found

on the right exterior side of the unit. See Figure 12.3 for

wire connection detail.