Framing and clearances – Heat & Glo Fireplace XLR-N-CE User Manual

Page 17

Advertising
background image

17

Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13

5

Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to

consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate

clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat-

ed out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are

FOR DESIGN PURPOSES ONLY. Illustrations/diagrams

are not drawn to scale. Actual installation may vary due to

individual design preference.

2,54 cm

A

E

A

B

C

TOP VENT

ONE 90º ELBOW

ALCOVE

INSTALLATION

D*

TOP VENT

ONE 90° ELBOW

B

F

Figure 5.1 Appliance Locations

A

B

C

D*

E

F

Centimeters

135

122

191

See Section D.

Figure 5.6

49

45

Advertising