Figure 10.17 Venting through the wall

K. Install Horizontal Termination Cap

WARNING! Risk of Fire! The telescoping flue section

of the termination cap MUST be used when connecting

vent.

• 3,8 cm minimum overlap of flue telescoping section

is required.

Failure to maintain overlap may cause overheating and

fire.

• Vent termination must not be recessed in the wall. Siding

may be brought to the edge of the cap base.

• Flash and seal as appropriate for siding material at

outside edges of cap.

• When installing a horizontal termination cap, follow the

cap location guidelines as prescribed by current local or

national codes and refer to Section 6 of this manual.

CAUTION! Risk of Burns! Local codes may require in-

stallation of a cap shield to prevent anything or anyone

from touching the hot cap.

Note: When using termination caps with factory-supplied heat

shield attached, no additional wall shield firestop is required on

the exterior side of a combustible wall.

INTERIOR

HEAT SHIELD OR

EXTENDED

HEAT SHIELD

WALL SHIELD

FIRESTOP

HEAT SHIELD

3,8 CM MIN.

OVERLAP

SHEATHING

SLIP SECTION

CAN BE EXTENDED

INNER VENT

OUTER VENT

EXTERIOR