Termination locations, Warning, A. vent termination minimum clearances – Heat & Glo Fireplace XLR-N-CE User Manual

Page 21

Advertising
background image

21

Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13

A. Vent Termination Minimum Clearances

Figure 6.1 Minimum Height From Roof To Lowest Discharge

Opening

H (MIN.) - MINIMUM HEIGHT FROM ROOF

TO LOWEST DISCHARGE OPENING

VERTICAL

WALL

TERMINATION

CAP

HORIZONTAL

OVERHANG

30,5 cm

X

ROOF PITCH

IS X/ 30,5 cm

LOWEST

DISCHARGE

OPENING

51 cm

6

Termination Locations

Fire Risk.
Maintain vent clearance to combustibles as

specified.

DO NOT pack air space with insulation or other

materials.

Failure to keep insulation or other materials away

from vent pipe may cause overheating and fire.

WARNING

Gas, Wood or Fuel Oil

Termination Cap

B

Gas

Termination

Cap **

A*

* If using decorative cap cover(s), this distance may need to be

increased. Refer to the installation instructions supplied with the

decorative cap cover.

** In a staggered installation with both gas and wood or fuel oil

terminations, the wood or fuel oil termination cap must be

higher than the gas termination cap.

A

B

15,2 cm (minimum) up to 50,8 cm

45,7 cm minimum

50,8 cm and over

0 cm minimum

Figure 6.2 Staggered Termination Caps

Angle

H (Min.) cm

0°-26.6° .......................................................... 30*
26.6°-30.3° .......................................................... 38*
30.3°-33.7° .......................................................... 46*
33.7°-36.9° .......................................................... 61*
36.9°-39.8° .......................................................... 76
39.8°-42.5° .......................................................... 99
42.5°-45.0° ........................................................1 22
45.0°-49.4° ........................................................1 52
49.4°-53.1° ........................................................1 83
53.1°-56.3° ........................................................2 13
56.3°-59.0° ........................................................2 29
59.0°-60.3° ........................................................2 44

*.91 M minimum in snow regions

Advertising