Figure 6.3 Minimum Clearances for Termination

A = 31 cm ......................clearances above grade, veranda,

porch, deck or balcony

B = 31 cm ......................clearances to window or door

that may be opened, or to perma-

nently closed window. (Glass)

C = 46 cm ......................vertical clearance to unventilated

soffit or to ventilated soffit located

above the terminal

76 cm .......................for vinyl clad soffits and below

electrical service

D = 23 cm .....................clearance to outside corner
E = 15 cm ......................clearance to inside corner
F

= 91 cm ......................not to be installed above a gas

meter/regulator assembly within 3

feet (90 cm) horizontally from the

center-line of the regulator

G = 1,8 m .......................clearance to gas service regulator

flue outlet

H = 31 cm ......................clearance to non-mechanical

air supply inlet to building or the

combustion air inlet to any other

appliance

i

= 1,8 m ......................clearance to a mechanical (pow-

ered) air supply inlet

** a vent shall not terminate directly above a sidewalk or paved driveway

which is located between two single family dwellings and serves both

dwellings.

*** only permitted if veranda, porch, deck or balcony is fully open on a

minimum of 2 sides beneath the floor, or meets Note 2.

Note 1: On private property where termination is less than 2.1 m above a

sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap

shield is suggested. (See vents components page)
Note 2: Termination in a covered alcove space (spaces open only on one

side and with an overhang) are permitted with the dimensions specified

for vinyl or non-vinyl siding and soffits.

1. There must be .91 m minimum

between termination caps.

2. All mechanical air intakes within 3 m of a

termination cap must be a minimum of .91 m below the termination cap.

3.

All gravity air intakes within .91 m of a termination cap must be a minimum

of .30 m below the termination cap.

(See Note 1)

(See Note 2)

Note 3: Local codes or regulations may require different clearances.
Note 4: Termination caps may be hot. Consider their proximity to

doors or other traffic areas.
Note 5: Location of the vent termination must not interfere with access

to the electrical service.
Vent system termination is

NOT permitted in screened porches.

Vent system termination is permitted in porch areas with two or more

sides open. You must follow all side walls, overhang and ground

clearances as stated in the instructions.
Heat & Glo assumes no responsibility for the improper performance

of the appliance when the venting system does not meet these

requirements.

C

J

B

D

i

B

F

G

B

A

A

E

X

V

V

V

V

V

V

V

M

H OR i

Electrical

Service

V

K

V

K

V

L

C

V

M*** = 46 cm ...................clearance under veranda, porch,

deck, balcony or overhang

107 cm ............ vinyl

N = 15 cm .............. non-vinyl sidewalls

31 cm .............. vinyl sidewalls

O = 46 cm .............. non-vinyl soffit and overhang

107 cm ............ vinyl soffit and overhang

P = 2.4 m

Q

MIN

R

MAX

1 cap

91 cm

2 x Q

ACTUAL

2 caps

1,8 m

1 x Q

ACTUAL

3 caps

2,7 m

2/3 x Q

ACTUAL

4 caps

3,7 m

1/2 x Q

ACTUAL

Q

MIN

= # termination caps x 3 R

MAX

= (2 / # termination caps) x Q

ACTUAL

Covered Alcove Applications

(See Note 1)

(See Note 5)

(See Note 5)

J** = 2.13 m. ................... clearance above paved

sidewalk or a paved driveway

located on

public property

K = 15 cm .................... clearance from sides of electri-

cal service

L = 31 cm ..................... clearance above electrical

service

Measure horizontal clearances from this surface.

Measure vertical clearances from this surface.

(See Note 2)

(See Note 2)