B. mantel and wall projections, C. facing material – Heat & Glo Fireplace XLR-N-CE User Manual

Page 47

Advertising
background image

47

Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13

B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-

ances to combustibles as specified. Framing closer than the

minimums listed must be constructed entirely of noncom-

bustible materials (i.e., steel studs, concrete board, etc.)

Failure to comply could cause fire.

Figure 13.5 Clearances To Combustible Mantels Or Other

Combustibles Above Appliance

Mantels (Combustible/Non-Combustible)

Figure 13.6 Non-Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

UNLIMITED

TOP VIEW

18 cm

8 cm

MINIMUM

36 cm

MIN.

30 cm

MAX.

1,3 cm

Thick Wall

Sheathing

MEASUREMENT

FROM TOP OF

FIREPLACE

OPENING

Note: For non-combustible fireplace finish material (marble,

stone, etc) specifications refer to Section 13.C.

Mantel Leg (Combustible/Non-Combustible)

C. Facing Material

• Facing and/or finishing materials must not interfere with

air flow through louvers, operation of louvers or doors,

or access for service.

• Facing and/or finishing materials must never overhang

into the glass opening.

• Observe all clearances when applying combustible

materials.

Figure 13.7 Overlap Fit Method (Tonic or Martini Decorative

Front)

FACTORY-INSTALLED

NON-COMBUSTIBLE BOARD

DRYWALL OR

EQUIVALENT (1,2 cm)

NON-COMBUSTIBLE

FINISHING MATERIAL

0 - 2,5 cm THICK

NON-COMBUSTIBLE

FINISHING MATERIAL

0 - 2,5 cm THICK

TONIC DECORATIVE

FRONT SHOWN

3,8 cm ABOVE STANDOFF

Both the Tonic and Martini decorative fronts can be in-

stalled with an “Overlap” or “Inside Fit” method:
Overlap Requirement: See Figure 13.7.
Inside Fit requirement: See Figure 13.8 and 13.9.
Non-Combustible Finish Materials

0 - 2,54 cm Thickness-Overlap Fit Method
Both the Tonic and Martini decorative fronts are designed

to overlap finish materials 0 cm to 2,54 cm thick. See

Figure 13.6.
NOTICE: This 2.54 cm maximum not only includes the

decorative finish materials (marble, tile, slate, etc) but

also the mortar or adhesive used to attach the decorative

finish material.
The non-combustible finish material can be installed up to

the fireplace opening.

WARNING! Risk of Fire! DO NOT apply combustible

materials beyond the minimum clearances. Comply with

all minimum clearances to combustibles as specified in

this manual. Overlapping materials could ignite and will

interfere with proper operation of doors and louvers.
WARNING! Risk of Fire! DO NOT install drywall or other

combustible materials over the factory-installed non-com-

bustible board. Overlapping materials could ignite.
Decorative facing material thickness is measured from

the face of the factory-installed non-combustible board.

See Figure 13.7

Advertising
This manual is related to the following products: