Use the diagnostic tool for troubleshooting. The executable is

/usr/local/bin/sv6diag

. More usage details can be found by view-

ing the man page for sv6diag, or running

sv6diag -h

. Diagnostic

results are generated as a table showing the pass/fail status for each
component in the system.

sv6diag runs the following sequence of tests:

Back - Verifies name resolution on slaves
Comp - Tests RS232 connectivity to the compositor(s)
Digi - Verifies connectivity to slaves through the Digi-Etherlite terminal
server
Forw - Verifies name resolution on master
Giga - Tests connectivity on 1000 baseT network
Ping - Verifies connectivity to terminal server
Rsh - Verifies Remote Shell Capability
Tnet - Tests connectivity on 10/100baseT network

Usage: To run the test suite, type:

sv6diag [-abcdglnprt]

Description:

Runs diagnostic tests on sv6 systems.
All tests run by default without logging.

Options:

a - Run all tests
b - Verify name resolution on slaves
c - Test connectivity to the compositor(s)
d - Verify connectivity to slaves through the terminal server
g - Test connectivity on 1000baseT network
l - Turn logging on
n - Verify name resolution on master
p - Verify connectivity to terminal server
r - Verify Remote Shell Capability
t - Test connectivity on 10/100baseT network

Executing sv6diag with no arguments runs all of the tests.