GFK-2489

Chapter 3 AP Management 3-31

3

RSG Entries

—This selection allows entry of key RSG parameters including Unit ID, COM

port setting, Mode, and Local IP Port on the screen shown below.

Remote Serial Wizard

—This tool assists you in adding or changing a configuration to

your remote serial gateway entries. These are the same settings contained in RSG Entries
Screen above, but the Remote Serial Wizard presents a step-by-step series of screens
with explanatory text to assist you in making your selections.

RSG Entries Menu

Entry #1 of 1

A) Unit ID

7728

B) Com Port

2

C) Mode

TCP Server

D) Local IP Port

30820

E) TCP Keepalive

5 seconds

N) Next Entry

X) Copy This Entry

P) Previous Entry

Y) Delete This Entry

S) Save Changes

Z) Delete All Entries

Select a letter to configure an item, <ESC> for prev menu

(TCP configuration; UDP is similar)

Unit ID

—Enter “Broadcast”, or enter the Unit ID of the Remote for unicast (directed) data.

The Unit ID defaults to the last four digits of the radio serial number, but can be set to any
32-bit integer.

COM Port

—Remote serial port with which to exchange data.

Mode

—TCP server or UDP.

Local IP Port

—The IP Port Number to which an application connects to exchange data

via the AP.

TCP Keepalive

—This value sets the number of seconds that a TCP connection can be

inactive before it is disconnected. If the value is set to zero, the port is effectively shut off.
[0-600; 5]