Maxon Telecom MODMAX MM-6280IND User Manual

Page 14

Advertising
background image

HSDPA Standard At Commands Page 14 of 61 Version 1.2

4800, 9600, 19200), (45, 50, 75, 110, 150, 300, 600, 38400,

57600, 115200, 230400)

+IPR=<value> Set value

+ICF Opt.

TE2-MT2 Character Framing. This extended-format

compound parameter is used to determine the local serial

port start-stop (asynchronous) character framing that the

MT2 shall use while accepting TE2 command set and while

transmitting information text and result codes to the TE2, if

this is not automatically determined (see +IPR).

+ICF? Shows current settings

+ICF=? Shows supported range

+ICF=<format_value,parity_value> sets value

<format> valid

numeric

values

0 auto

detect

[NOT

SUPPORTED]

1 8Data

2Stop

2 8Data

1Parity

1Stop

3 8Data

1Stop

(Default)

4 7Data

2Stop

5 7Data

1Parity

1Stop

6 7Data

1Stop

<parity> defined

numeric

values

0 odd

1 even

2

Mark [NOT SUPPORTED]

3 space

(Default)

supported

+IFC Opt.

TE2-MT2 Local Flow Control. This extended-format

compound parameter is used to control the operation of

local flow control between the TE2 and MT2

[1]

.

<c_by_t> Description

0 None

1 Xon/Xoff

local

DC1/DC3 on circuit 103; do not pass

DC1/DC3 characters to the remote

DCE.

2

Circuit 133 (Ready for Receiving)

(Default)

supported

Advertising