MultiVOIP FXS User Guide

Mechanical Installation & Cabling

47

Cabling Procedure for MVPFXS-8/16/24

Prerequisites: To complete the MultiVOIP cabling procedure, you must have:

• One RJ-21 Cable. That cable must have a male end to fit the MultiVOIP.

The other end must fit your telephony equipment.

• Two common network cables (RJ45-to-RJ45).

Cabling entails connecting:

- the MultiVOIP to ground ,
- the MultiVOIP to power,
- the MultiVOIP to your LAN/WAN network,
- the control computer to your LAN/WAN network,
- the MultiVOIP to your telephone equipment, and
- connecting, optionally, the MultiVOIP Console port to the control computer’s serial port (needed

for initial setup only if your system cannot use the voip’s default IP address).

1. Ground Connection. Ensure that the unit is properly connected to an earth ground.

To do this, connect a grounding wire between the chassis grounding screw (see Figure 3-5) and a metallic

object that will provide an electrical ground. In some cases, mounting racks will can serve as an adequate

earth ground.

Console Port Connection

RJ-45

Connectors

Grounding

Screw

Grounding

Cable

DB-9 Connector to

Computer Serial Port

for Console Functions

WAN/Ethernet Connection

VOIP Control

through

Web GUI

Cable hold-down
device is included.

RJ-21

The RJ21 50-pin connector can

terminate in either a terminal block,

a key system, or a PBX station card.

In each case, it offers FXS service

to phones or fax machines.

Voip’s Default IP

= 192.168.2.1

Control Computer’s IP

= 192.168. 2. x

**

**

Note: If network configuration makes it

difficult or impossible to assign the

control computer to 192.168.2.x,

then the voip’s IP must be reset

using the voip’s Console connection.

See User Guide for details.

CO NSOL E

WAN

T ELECO M

25

1

25

1

5 0

50

26

26

Figure 3-5: Cabling for the MVPFXS-8/16/24