2-1 (Page 6 of 23). POST and Diagnostics and Utilities Index

for Symptoms, Messages, Error Codes, or Beeps

Symptoms, Messages, Error
Codes, or Beeps

Action/FRU

Invalid Format - Bad Track

error message appears when
trying to format a known-good
diskette.

Diskette drive connection/cable
Diskette drive
System board

Incorrect memory size shown or
repeated during POST.

“Memory” on page 2-37.

Invalid Time
Clock/DOS time mismatch.
Back-up clock and DOS time of
day settings do not match.

RTC Battery
System Board

Joystick does not respond at all.

1. Ensure the joystick is plugged

completely into the joystick/MIDI
adapter plug on the system board and
secured with the screws on the adapter
plug.

2. Verify that the software application

used with the joystick has joystick
support.

3. Ensure the joystick is enabled in the

software application. This might
require entering keystrokes or a
configuration utility in the software
application.

If the above steps find no problem, see the
“Joystick does not work correctly” symptom
below.

Joystick does not work correctly
(installation is correct—see
above symptom).

1. Disable the joystick in the software

application.

2. Enable the mouse as the input device

in the software application.

3. If the mouse works in the software

application, replace the joystick. If the
symptom remains, replace the system
board.

4. If the mouse does not work, check the

software application troubleshooting
information provided by the
manufacturer.