Vol. 3A 14-13

MACHINE-CHECK ARCHITECTURE

FOR error-reporting banks (0 through MAX_BANK_NUMBER)
DO

(Optional for BIOS and OS) Log valid errors
(OS only) IA32_MCi_STATUS

0;

OD

FI

FI

FI

Setup the Machine Check Exception (#MC) handler for vector 18 in IDT

Set the MCE bit (bit 6) in CR4 register to enable Machine-Check Exceptions

FI

14.6. INTERPRETING THE MCA ERROR CODES

When the processor detects a machine-check error condition, it writes a 16-bit error code to the
MCA error code field of one of the IA32_MCi_STATUS registers and sets the VAL (valid) flag
in that register. The processor may also write a 16-bit model-specific error code in the
IA32_MCi_STATUS register depending on the implementation of the machine-check architec-
ture of the processor.

The MCA error codes are architecturally defined for IA-32 processors. However, the specific
IA32_MCi_STATUS register that a code is ‘written to’ is model specific. To determine the cause
of a machine-check exception, the machine-check exception handler must read the VAL flag for
each IA32_MCi_STATUS register. If the flag is set, the machine check-exception handler must
then read the MCA error code field of the register. It is the encoding of the MCA error code field
[15:0] that determines the type of error being reported and not the register bank reporting it.

There are two types of MCA error codes: simple error codes and compound error codes.